Biochemical Oxygen Demand

views updated

Biochemical oxygen demand


The biochemical oxygen demand (BOD) test is an indirect measure of the biodegradable organic matter in an aqueous sample. The test is indirect because oxygen used by microbes as they degrade organic matter is measured, rather than the depletion of the organic materials themselves. Generally, the test is performed over a five-day period (BOD5) at 68°F (20°C) in 10 fl oz (300 ml) bottles incubated in the dark to prevent interference from algal growth. Dissolved oxygen (DO) levels (in mg/l) are measured on day zero and at the end of the test. The following equation relates how the BOD5 of a sample is calculated:

Note that in the above equation "ml sample" refers to the amount of sample that is placed in a 300 ml BOD bottle. This is critical in doing a test because if too much sample is added to a BOD bottle, microbes will use all the DO in the water (i.e., DOafter 5 days=0) and a BOD5 cannot be calculated. Thus, the DO uptake at various dilutions of a given sample are made. One way of making the dilutions is to add different amounts of sample to different bottles. The bottles are then filled with dilution water which is saturated with oxygen, contains various nutrients, is at a neutral pH , and is very pure so as not to create any interference. Researchers attempt to identify a dilution which will provide for a DO uptake of greater than or equal to 2 mg/l and a DO residual of greater than or equal to 0.5–1.0 mg/l.

In some cases compounds or ions may be present in a sample that will inhibit microbes from degrading organic materials in the sample, thereby resulting in an artificially low or no BOD. Other times, the right number and/or types of microbes are not present, so the BOD is inaccurate. Samples may be "seeded" with microbes to compensate for these problems. The absence of a required nutrient will also make the BOD test invalid.

Thus, a number of factors can influence the BOD, and the test is known to be rather imprecise (i.e., values obtained vary by 10–15% of the actual value in a good test). However, the test continues to be a primary index of how well waters need to be treated or are treated and of the quality of natural waters. If wastes are not treated properly and contain too much BOD, the wastes may create serious oxygen deficits in environmental waters. The saturation concentration of oxygen in water varies somewhat with temperature and pressure but is often only in the area of 8–10 mg/l or less. To serve as a reference, the BOD5 of raw, domestic wastewater ranges from about 100–300 mg/l. The demand for oxygen by the sewage is therefore clearly much greater than the amount of oxygen that water can hold in a dissolved form. To determine allowable BOD levels for a wastewater discharge , one must consider the relative flows/volumes of the wastewater and receiving (natural) water, temperature, reaeration of the natural water, biodegradation rate, input of other wastes, influence of benthic deposits and algae, DO levels of the wastewater and natural water, and condition/value of the receiving water.

[Gregory D. Boardman ]


RESOURCES

BOOKS


Corbitt, R. A. Standard Handbook of Environmental Engineering. New York: McGraw-Hill, 1990.

Davis, M. L., and D. A. Cornwell. Introduction to Environmental Engineering. New York: McGraw-Hill, 1991.

Tchobanoglous, G., and E. D. Schroeder. Water Quality. Reading, MA: Addison-Wesley, 1985.

Viessman Jr., W., and M. J. Hammer. Water Supply and Pollution Control. 5th ed. New York, Harper Collins, 1993.

More From encyclopedia.com